Step by step
- Photograph it straight on, with a tape or a coin for scale, and again from further back to show the opening.
- Measure the widest point and write the number; a crack that is 1 mm today and 3 mm in six weeks is the finding.
- Look outside at the same corner for a stepped crack in the brickwork.
- Grade low for hairline and stable, medium if wider than 2 mm or recurring after filling, high if displaced, stepped outside or growing.
Punch List AI keeps the photo's date and, if you allow it, GPS under each photo on the report. Photograph the same crack on the re-inspection and close the item with the after photo, or reopen it with the new width if it has moved.
Related questions
Should I put a crack monitor on it?
For anything you grade medium or above, yes, a dated photo with a scale beside it is a crack monitor a client understands.
Does the builder have to fix hairline cracks?
In the UK, warranty tolerances generally exclude cracks under about 2 mm from being defects; they are usually made good at the end of the defects period rather than at handover.
Try it on your next walk
Free to download; the first project is free for good. No account.