    "summary": "Covering, flashings, ridges and verges, gutters and downpipes, then the roof space from inside.",
    "sections": [
      {
        "room": "Covering",
        "checks": [
          {
            "text": "No slipped, cracked or missing tiles or slates",
            "category": "structural"
          },
          {
            "text": "Courses straight; laps correct; no exposed fixings",
            "category": "structural"
          },
          {
            "text": "Moss and debris cleared; no ponding on flat areas",
            "category": "cosmetic"
          },
          {
            "text": "Flat roof membrane bonded, no blisters, laps sealed",
            "category": "structural"
          }
        ]
      },
      {
        "room": "Flashings and penetrations",
        "checks": [
          {
            "text": "Lead or proprietary flashings dressed and pointed at every abutment",
            "category": "structural"
          },
          {
            "text": "Soil vent, flue and extract terminals sealed with a proper collar",
            "category": "structural"
          },
          {
            "text": "Roof windows flashed; no daylight at the kit",
            "category": "structural"
          },
          {
            "text": "Solar panel fixings sealed; cable entries weathered",
            "category": "electrical"
          }
        ]
      },
      {
        "room": "Ridges, hips and verges",
        "checks": [
          {
            "text": "Ridge and hip tiles secure, dry-fix or sound mortar",
            "category": "structural"
          },
          {
            "text": "Verges closed; no gaps for birds or wind uplift",
            "category": "structural"
          },
          {
            "text": "Eaves: underlay carries into the gutter; comb filler fitted",
            "category": "structural"
          }
        ]
      },
      {
        "room": "Gutters and downpipes",
        "checks": [
          {
            "text": "Gutters fall to the outlet; joints sealed; brackets tight",
            "category": "plumbing"
          },
          {
            "text": "No standing water or overflow marks on the fascia",
            "category": "plumbing"
          },
          {
            "text": "Downpipes connected to the drain, not discharging at the wall base",
            "category": "plumbing"
          },
          {
            "text": "Gulleys clear and gratings fitted",
            "category": "plumbing"
          },
          {
            "text": "Fascia and soffit sound; vents unobstructed",
            "category": "finishing"
          }
        ]
      },
      {
        "room": "Roof space from inside",
        "checks": [
          {
            "text": "No daylight visible except at vents",
            "category": "structural"
          },
          {
            "text": "No damp staining on timbers, underlay or insulation",
            "category": "structural"
          },
          {
            "text": "Insulation continuous, not blocking eaves ventilation",
            "category": "finishing"
          },
          {
            "text": "Water tank lidded and insulated; pipes lagged",
            "category": "plumbing"
          },
          {
            "text": "Fire stopping at party walls complete",
            "category": "safety"
          }
        ]
      }
    ]
  }
}